Zephyr API Documentation 4.2.0-rc3
A Scalable Open Source RTOS
 4.2.0-rc3
health_faults.h File Reference

Health faults. More...

Go to the source code of this file.

Macros

#define BT_MESH_HEALTH_FAULT_NO_FAULT   0x00
 No fault has occurred.
#define BT_MESH_HEALTH_FAULT_BATTERY_LOW_WARNING   0x01
#define BT_MESH_HEALTH_FAULT_BATTERY_LOW_ERROR   0x02
#define BT_MESH_HEALTH_FAULT_SUPPLY_VOLTAGE_TOO_LOW_WARNING   0x03
#define BT_MESH_HEALTH_FAULT_SUPPLY_VOLTAGE_TOO_LOW_ERROR   0x04
#define BT_MESH_HEALTH_FAULT_SUPPLY_VOLTAGE_TOO_HIGH_WARNING   0x05
#define BT_MESH_HEALTH_FAULT_SUPPLY_VOLTAGE_TOO_HIGH_ERROR   0x06
#define BT_MESH_HEALTH_FAULT_POWER_SUPPLY_INTERRUPTED_WARNING   0x07
#define BT_MESH_HEALTH_FAULT_POWER_SUPPLY_INTERRUPTED_ERROR   0x08
#define BT_MESH_HEALTH_FAULT_NO_LOAD_WARNING   0x09
#define BT_MESH_HEALTH_FAULT_NO_LOAD_ERROR   0x0A
#define BT_MESH_HEALTH_FAULT_OVERLOAD_WARNING   0x0B
#define BT_MESH_HEALTH_FAULT_OVERLOAD_ERROR   0x0C
#define BT_MESH_HEALTH_FAULT_OVERHEAT_WARNING   0x0D
#define BT_MESH_HEALTH_FAULT_OVERHEAT_ERROR   0x0E
#define BT_MESH_HEALTH_FAULT_CONDENSATION_WARNING   0x0F
#define BT_MESH_HEALTH_FAULT_CONDENSATION_ERROR   0x10
#define BT_MESH_HEALTH_FAULT_VIBRATION_WARNING   0x11
#define BT_MESH_HEALTH_FAULT_VIBRATION_ERROR   0x12
#define BT_MESH_HEALTH_FAULT_CONFIGURATION_WARNING   0x13
#define BT_MESH_HEALTH_FAULT_CONFIGURATION_ERROR   0x14
#define BT_MESH_HEALTH_FAULT_ELEMENT_NOT_CALIBRATED_WARNING   0x15
#define BT_MESH_HEALTH_FAULT_ELEMENT_NOT_CALIBRATED_ERROR   0x16
#define BT_MESH_HEALTH_FAULT_MEMORY_WARNING   0x17
#define BT_MESH_HEALTH_FAULT_MEMORY_ERROR   0x18
#define BT_MESH_HEALTH_FAULT_SELF_TEST_WARNING   0x19
#define BT_MESH_HEALTH_FAULT_SELF_TEST_ERROR   0x1A
#define BT_MESH_HEALTH_FAULT_INPUT_TOO_LOW_WARNING   0x1B
#define BT_MESH_HEALTH_FAULT_INPUT_TOO_LOW_ERROR   0x1C
#define BT_MESH_HEALTH_FAULT_INPUT_TOO_HIGH_WARNING   0x1D
#define BT_MESH_HEALTH_FAULT_INPUT_TOO_HIGH_ERROR   0x1E
#define BT_MESH_HEALTH_FAULT_INPUT_NO_CHANGE_WARNING   0x1F
#define BT_MESH_HEALTH_FAULT_INPUT_NO_CHANGE_ERROR   0x20
#define BT_MESH_HEALTH_FAULT_ACTUATOR_BLOCKED_WARNING   0x21
#define BT_MESH_HEALTH_FAULT_ACTUATOR_BLOCKED_ERROR   0x22
#define BT_MESH_HEALTH_FAULT_HOUSING_OPENED_WARNING   0x23
#define BT_MESH_HEALTH_FAULT_HOUSING_OPENED_ERROR   0x24
#define BT_MESH_HEALTH_FAULT_TAMPER_WARNING   0x25
#define BT_MESH_HEALTH_FAULT_TAMPER_ERROR   0x26
#define BT_MESH_HEALTH_FAULT_DEVICE_MOVED_WARNING   0x27
#define BT_MESH_HEALTH_FAULT_DEVICE_MOVED_ERROR   0x28
#define BT_MESH_HEALTH_FAULT_DEVICE_DROPPED_WARNING   0x29
#define BT_MESH_HEALTH_FAULT_DEVICE_DROPPED_ERROR   0x2A
#define BT_MESH_HEALTH_FAULT_OVERFLOW_WARNING   0x2B
#define BT_MESH_HEALTH_FAULT_OVERFLOW_ERROR   0x2C
#define BT_MESH_HEALTH_FAULT_EMPTY_WARNING   0x2D
#define BT_MESH_HEALTH_FAULT_EMPTY_ERROR   0x2E
#define BT_MESH_HEALTH_FAULT_INTERNAL_BUS_WARNING   0x2F
#define BT_MESH_HEALTH_FAULT_INTERNAL_BUS_ERROR   0x30
#define BT_MESH_HEALTH_FAULT_MECHANISM_JAMMED_WARNING   0x31
#define BT_MESH_HEALTH_FAULT_MECHANISM_JAMMED_ERROR   0x32
#define BT_MESH_HEALTH_FAULT_VENDOR_SPECIFIC_START   0x80
 Start of the vendor specific fault values.

Detailed Description

Health faults.