maxim,max20335-regulator

Vendor: Maxim Integrated Products

Note

An implementation of a driver matching this compatible is available in drivers/regulator/regulator_max20335.c.

Description

Maxim MAX20335 PMIC

The PMIC has two buck converters and three LDOs. All need to be defined as
children nodes, strictly following the BUCK1..2, LDO1..3 node names. For
example:

pmic@28 {
  reg = <0x28>;
  ...
  regulators {
    compatible = maxim,max20335-regulator";

    BUCK1 {
      /* all properties for BUCK1 */
    };
    BUCK2 {
      /* all properties for BUCK2 */
    };
    LDO1 {
      /* all properties for LDO1 */
    };
    LDO2 {
      /* all properties for LDO2 */
    };
    LDO3 {
      /* all properties for LDO3 */
    };
  };
};

Properties

Top level properties

These property descriptions apply to “maxim,max20335-regulator” nodes themselves. This page also describes child node properties in the following sections.

Properties not inherited from the base binding file.

(None)

Child node properties

Name

Type

Details

regulator-init-microvolt

int

Voltage set during initialisation

regulator-min-microvolt

int

smallest voltage consumers may set

regulator-max-microvolt

int

largest voltage consumers may set

regulator-init-microamp

int

Current set during initialisation

regulator-max-microamp

int

largest current consumers may set

regulator-always-on

boolean

boolean, regulator should never be disabled

regulator-boot-on

boolean

bootloader/firmware enabled regulator.
It's expected that this regulator was left on by the bootloader.
If the bootloader didn't leave it on then OS should turn it on
at boot but shouldn't prevent it from being turned off later.
This property is intended to only be used for regulators where
software cannot read the state of the regulator.

regulator-initial-mode

int

Initial operating mode. The set of possible operating modes depends on the
capabilities of every hardware so each device binding documentation
explains which values the regulator supports.

regulator-allowed-modes

array

List of operating modes that software is allowed to configure for the
regulator at run-time. Elements may be specified in any order. The set of
possible operating modes depends on the capabilities of every hardware so
each device binding document explains which values the regulator supports.