renesas,ra-ctsu

Vendor: Renesas Electronics Corporation

Note

An implementation of a driver matching this compatible is available in drivers/input/input_renesas_ra_ctsu.c.

Description

Renesas RA Capacitive Sensing Unit

Properties

Top level properties

These property descriptions apply to “renesas,ra-ctsu” nodes themselves. This page also describes child node properties in the following sections.

Properties not inherited from the base binding file.

Name

Type

Details

pinctrl-0

phandles

Pin configuration/s for the first state. Content is specific to the
selected pin controller driver implementation.

This property is required.

variant

string

Determine which ctsu device is in use

This property is required.

Legal values: 'ctsua', 'ctsu2'

clock-div

int

Select divider value for operating input clock. Default as div by 1.

Default value: 1

Legal values: 1, 2, 4, 8

pwr-supply-sel

string

CTSU Transmission Power Supply Select (for both CTSUa and CTSU2).

Default value: internal-power

Legal values: 'vcc', 'internal-power'

pwr-supply-sel2

string

CTSU Transmission Power Supply Select 2 (CTSU2 Only)

Default value: pwr-supply-sel

Legal values: 'pwr-supply-sel', 'vcc-private'

atune1

string

CTSU Power Supply Capacity Adjustment (CTSUa Only):
- "normal": 40uA
- "high": 80uA

Default value: normal

Legal values: 'normal', 'high'

atune12

int

CTSU Power Supply Capacity Adjustment in uA (CTSU2 Only)

Default value: 40

Legal values: 80, 40, 20, 160

measure-mode

string

CTSU Measurement Mode Select

Default value: self-multi-scan

Legal values: 'self-multi-scan', 'mutual-full-scan', 'mutual-cfc-scan', 'current-scan', 'correction-scan', 'diagnosis-scan'

po-sel

string

CTSU Non-Measured Channel Output Select (CTSU2 Only)

Default value: same-pulse

Legal values: 'low-gpio', 'hi-z', 'low', 'same-pulse'

tscap-gpios

phandle-array

CTSU TSCAP Pin. This pin is used to discharge the capacitior by
control to output low, before switching to CTSU function.

This property is required.

pinctrl-1

phandles

Pin configuration/s for the second state. See pinctrl-0.

pinctrl-2

phandles

Pin configuration/s for the third state. See pinctrl-0.

pinctrl-3

phandles

Pin configuration/s for the fourth state. See pinctrl-0.

pinctrl-4

phandles

Pin configuration/s for the fifth state. See pinctrl-0.

pinctrl-names

string-array

Names for the provided states. The number of names needs to match the
number of states.

Child node properties

Name

Type

Details

ctsuchac

array

TSCAP pin enable mask. Expected fields, in order, are:
- ctsuchac0: TS00-TS07 enable mask
- ctsuchac1: TS08-TS15 enable mask
- ctsuchac2: TS16-TS23 enable mask
- ctsuchac3: TS24-TS31 enable mask
- ctsuchac4: TS32-TS39 enable mask

Default value: [0, 0, 0, 0, 0]

ctsuchtrc

array

TSCAP pin mutual-tx mask. Expected fields, in order, are:
- ctsuchtrc0: TS00-TS07 mutual-tx mask
- ctsuchtrc1: TS08-TS15 mutual-tx mask
- ctsuchtrc2: TS16-TS23 mutual-tx mask
- ctsuchtrc3: TS24-TS31 mutual-tx mask
- ctsuchtrc4: TS32-TS39 mutual-tx mask

Default value: [0, 0, 0, 0, 0]

rx-count

int

The number of RX channels to be used. This should be set to the number of
channels that are enabled in the ctsuchac0-4 properties.

tx-count

int

The number of TX channels to be used. This should be set to the number of
channels that are enabled in the ctsuchtrc0-4 properties.

ssdiv

string-array

CTSU Spectrum Diffusion Frequency Division Setting (CTSUa Only)

Default value: ['4.00']

Legal values: '4.00', '2.00', '1.33', '1.00', '0.80', '0.67', '0.57', '0.50', '0.44', '0.40', '0.36', '0.33', '0.31', '0.29', '0.27', '0.00'

so

array

CTSU Sensor Offset Adjustment

Default value: [0]

snum

array

CTSU Measurement Count Setting

Default value: [0]

sdpa

array

CTSU Base Clock Setting

Default value: [0]

on-freq

int

The cumulative number of determinations of ON.

off-freq

int

The cumulative number of determinations of OFF.

drift-freq

int

Base value drift frequency (0 mean no use).

cancel-freq

int

Maximum continuous ON (0 mean no use).

num-moving-avg

int

The number of samples to use for moving average. If set to 0, no moving average is applied.
This is useful for smoothing the sensor readings.