Zephyr API Documentation 4.5.99
A Scalable Open Source RTOS
|
Peacefair PZEM-004T AC energy meter. More...
Files | |
| file | pzem004t.h |
| Header file for extended sensor API of PZEM-004T sensor. | |
Enumerations | |
| enum | sensor_channel_pzem004t { SENSOR_CHAN_PZEM004T_ENERGY = SENSOR_CHAN_PRIV_START , SENSOR_CHAN_PZEM004T_POWER_FACTOR , SENSOR_CHAN_PZEM004T_ALARM_STATUS , SENSOR_CHAN_PZEM004T_POWER_ALARM_THRESHOLD , SENSOR_CHAN_PZEM004T_MODBUS_RTU_ADDRESS , SENSOR_CHAN_PZEM004T_ADDRESS_INST_SET , SENSOR_CHAN_PZEM004T_RESET_ENERGY } |
| Custom sensor channels for PZEM-004T. More... | |
| enum | sensor_attribute_pzem004t { SENSOR_ATTR_PZEM004T_POWER_ALARM_THRESHOLD = SENSOR_ATTR_PRIV_START , SENSOR_ATTR_PZEM004T_MODBUS_RTU_ADDRESS , SENSOR_ATTR_PZEM004T_ADDRESS_INST_SET , SENSOR_ATTR_PZEM004T_RESET_ENERGY } |
| Custom sensor attributes for PZEM-004T. More... | |
Peacefair PZEM-004T AC energy meter.
#include <zephyr/drivers/sensor/pzem004t.h>
Custom sensor attributes for PZEM-004T.
| Enumerator | |
|---|---|
| SENSOR_ATTR_PZEM004T_POWER_ALARM_THRESHOLD | Active power alarm threshold, in W. |
| SENSOR_ATTR_PZEM004T_MODBUS_RTU_ADDRESS | Modbus address of the device. Only set it with a single device connected to the bus. |
| SENSOR_ATTR_PZEM004T_ADDRESS_INST_SET | Modbus address the driver instance uses to reach the device. This does not change the address of the device itself. |
| SENSOR_ATTR_PZEM004T_RESET_ENERGY | Reset the energy counter of the device. Requires |
#include <zephyr/drivers/sensor/pzem004t.h>
Custom sensor channels for PZEM-004T.
| Enumerator | |
|---|---|
| SENSOR_CHAN_PZEM004T_ENERGY | Active energy accumulated over time, in Wh. |
| SENSOR_CHAN_PZEM004T_POWER_FACTOR | Power factor, the ratio of real power to apparent power, with 0.01 resolution. |
| SENSOR_CHAN_PZEM004T_ALARM_STATUS | Alarm status: 0xFF when the active power is above the power alarm threshold, 0x00 otherwise. |
| SENSOR_CHAN_PZEM004T_POWER_ALARM_THRESHOLD | Active power alarm threshold, in W. |
| SENSOR_CHAN_PZEM004T_MODBUS_RTU_ADDRESS | Modbus address of the device. Only set it with a single device connected to the bus. |
| SENSOR_CHAN_PZEM004T_ADDRESS_INST_SET | Modbus address the driver instance uses to reach the device. This does not change the address of the device itself. |
| SENSOR_CHAN_PZEM004T_RESET_ENERGY | Reset the energy counter of the device. Requires |